In a progressive lens, a small measurement error means the customer can't find the near zone and the lens has to be made again. Most orders sent back by labs come down to one of these five mistakes.

In this article5 sections
  1. 1. Settling for the total PD
  2. 2. Measuring fitting height before the frame is chosen
  3. 3. Skipping the pantoscopic angle and wrap
  4. 4. Copying the ADD from an old prescription
  5. 5. Leaving out the frame measurements

1. Settling for the total PD

Progressive lenses need a separate PD for each eye. Most faces are not symmetrical; splitting the total PD in two shifts the corridor away from the pupil.

2. Measuring fitting height before the frame is chosen

Fitting height is measured after the chosen frame has been adjusted to the customer's face. A measurement taken with a display frame can shift by millimetres in the new frame.

3. Skipping the pantoscopic angle and wrap

For personalised progressive lenses the lab asks for these values. Left blank, standard values are used and the lens loses its advantage.

4. Copying the ADD from an old prescription

The ADD value changes quickly after 45. If the new prescription has no value, confirm it with the doctor before sending the order.

5. Leaving out the frame measurements

If the box width, bridge and frame height are missing, the lab has to choose the shortest corridor.

Related articles

A spectacle temple and hinge
Prescriptions and lensesWays to shorten turnaround when working with a lab
Close-up of an optical lens
Prescriptions and lenses3 questions to ask before choosing an anti-reflective coating
Prescriptions and lenses

The 5 most common measurement mistakes in progressive lens orders

A wrong PD or a missing fitting height means the progressive lens has to be remade. Here are the five measurements to check before the order goes to the lab.

Product teamOptikCore · · 2 min read
An optical lens refracting light

In a progressive lens, a small measurement error means the customer can't find the near zone and the lens has to be made again. Most orders sent back by labs come down to one of these five mistakes.

1. Settling for the total PD

Progressive lenses need a separate PD for each eye. Most faces are not symmetrical; splitting the total PD in two shifts the corridor away from the pupil.

2. Measuring fitting height before the frame is chosen

Fitting height is measured after the chosen frame has been adjusted to the customer's face. A measurement taken with a display frame can shift by millimetres in the new frame.

3. Skipping the pantoscopic angle and wrap

For personalised progressive lenses the lab asks for these values. Left blank, standard values are used and the lens loses its advantage.

4. Copying the ADD from an old prescription

The ADD value changes quickly after 45. If the new prescription has no value, confirm it with the doctor before sending the order.

5. Leaving out the frame measurements

If the box width, bridge and frame height are missing, the lab has to choose the shortest corridor.